Select industry:
Dairy industry
Additional Information:
+38 (044) 247-04-11
+38 (057) 760-48-11
+38 (067) 360-48-11
+38 (073) 360-48-11
E-MAIL: MANAGER@SOLNECHNOE.COM.UA
Dimensions:
2700х1450х2000
Pasteurization and cooling units are designed for simultaneous rapid heating and cooling of the product (milk, water, juices, wine, kvass, beer, etc.) in the stream to a predetermined temperature. Energy savings of up to 93% in the regeneration section. Name POUE-1, 0 POUE-1, 5 POUE-3 Productivity, l / h 1000 1500 3500 Temperature, ° С - product inlet 6 6 6 -pasteurization of the product 78 +/- 2 78 +/- 2 78 +/- 2 products at the outlet without cooling 11 11 11 products at the outlet with cooling 4 ... 6 4 ... 6 4 ... 6 Heat recovery,% 93 93 93 Installed power, kW 30 48 48 Power in pasteurization mode, kW 15 18 24 Holding time , sec 20 20 20
Contact the author of the ad